Next® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4) |NEB酶试剂 New England Biolabs

上海金畔生物科技有限公司代理New England Biolabs(NEB)酶试剂全线产品,欢迎访问官网了解更多产品信息和订购。

产品信息

NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) are built for more streamlined and informative NGS multiplexing, tracking the sequencing reaction at the individual molecule level and enabling bioinformatic removal of misassigned reads for optimal accuracy. These index adaptors contain a pair of unique dual indices (i5 and i7) and one UMI sequence, making the resulting library multiplex-ready, with or without PCR. This set includes 96 unique dual index UMI adaptors, packaged in a single-use 96-well plate with a pierceable foil seal. The universal primer mix is supplied in a separate vial.

The NEBNext line of Multiplex Oligos can be used with NEBNext sample prep products or other standard Illumina-compatible library preparation protocols. In addition to this set, there are three other sets of NEBNext Unique Dual Index UMI Adaptors for DNA (NEB #E7395, #E7874, #E7876) for multiplexing of up to 384 samples; additional index adaptors with UMIs are available for RNA-seq (NEB #E7416). For multiplexing without UMIs, NEBNext offers several options for added flexibility, including unique dual index primers (NEB #6440, NEB #6442, NEB #E6444, NEB #E6446, and NEB #E6448), dual index primers (NEB #E7600 and NEB #E7780), and single primer sets (in 12- and 96-index formats; NEB #E7335, NEB #E7500, NEB #E7710, NEB #E7730, NEB #E6609), as well as an option compatible with EM-seq™ and bisulfite sequencing (NEB #E7140). 

For larger volume requirements,  customized and/or bulk packaging is available through our Customized Solutions Team. Please contact us at [email protected].

NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 3) enable both PCR-free and amplification-based workflows for DNA library preparation. Refer to the below diagram for the differences between the two options.

Figure 1. NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) Workflow

Next® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4) |

Figure 2. NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) allow higher ligation efficiency.

Next® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4) |

A. Libraries were prepared with 100, 250, and 500 ng inputs of human cell line NA19240 genomic DNA (Coriell Institute for Biomedical Research) and unique dual index adaptors from different suppliers using the NEBNext Ultra™ II FS DNA Library Prep Kit (NEB #E7805) without PCR amplification. The adaptors used were NEBNext Unique Dual Index UMI Adaptrs, xGen® Dual Index UMI Adapters (IDT®) and Nextflex® Unique Dual index Barcodes 1-96 (Bioo Scientific®). Two rounds of SPRIselect bead-based cleanup steps were performed post-ligation, and libraries were quantified by qPCR (NEBNext Library Quant Kit, NEB #E7630).  
B. 90 libraries were prepared with 100 ng NA19240 genomic DNA using the Ultra II FS DNA Library Prep Kit without PCR amplification in a 96-well plate. For the 90 libraries, 30 different adaptors each from NEB, IDT, and Bioo were used for ligation. Libraries were cleaned up and quantitated by qPCR. 
Figure 3. NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) allow more-sensitive, low-frequency variant detection.

Next® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4) |

AcroMetrix® Oncology Hotspot Control DNA (Thermo Scientific®) was used as a mutation DNA source (> 500 mutations with 5-35% allele frequency) and mixed with NA19240 genomic DNA at various ratios to generate a range of allele frequencies (5%-35%, 2.5%-17.5% and 1%-7%). Libraries were constructed using NEBNext Ultra II DNA Library Prep Kit (NEB #E7645) with NEBNext Unique Dual Index UMI Adaptors, and multiplex hybrid capture was performed on all samples using a customized panel for 152 genes from Twist Bioscience®. Libraries were sequenced on a NovaSeq® 6000 (PE140), and reads were downsampled to 110 Million (Seqtk Sample) and mapped to GRCh38 with BWA MEM (0.7.17). Mapped reads were analyzed by MarkDuplicates (Picard 2.20.6) without utilizing UMI information or by building UMI consensus sequences (Fgbio 0.8.1). The final BAM files were used to call somatic variants with Strelka2 (2.9.10).
A. The number of total and correct SNV calls increased when using UMI information for duplicate removal and consensus sequence-based error correction. 
B. The sensitivity of variant detection was improved with UMI consensus calling. The lower the allele frequency, the more benefit provided by UMI information in SNV detection.
Figure 4. NEBNext Unique Dual Index UMI Adaptors DNA Set 4 provides consistent library yields

Next® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4) |

96 Libraries were each prepared with 50 ng input of human cell line NA19240 genomic DNA (Coriell Institute for Biomedical Research) and the NEBNext Unique Dual Index UMI Adaptors DNA Set 3 using the NEBNext Ultra II FS PCR-free DNA Library Prep Kit (NEB #E6177) in a 96 well plate. Library cleanup was followed by qPCR quantification. Library concentrations ranged from 7.3 nM to 3.4 nM with a 2.1-fold difference across all 96 adaptors.
Figure 5.  NEBNext Unique Dual Index UMI Adaptors DNA Set 4 provides consistent clustering efficiency on MiSeq® and NovaSeq 6000

Next® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4) |

Fig Desc: 96 libraries prepared using the NEBnext Unique Dual Index UMI Adaptors DNA Set 2 and the NEBNext Ultra II FS PCR-free DNA Library Prep Kit (NEB #E6177) were pooled at equimolar concentrations and sequenced on the Illumina MiSeq and NovaSeq 6000 instruments. The total number of reads from all libraries were summed, and the fraction of the total reads contributed by each library was determined (expected faction per library = 1.04%). All 96 libraries clustered efficiently and were represented at approximately the expected frequency on both platforms.
Figure 6.  All libraries prepared with 384 NEBNext Unique Dual Index UMI Adaptors cluster evenly on the Illumina NovaSeq 6000

Next® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4) | 

384 libraries prepared using the NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4 and the NEBNext Ultra II FS PCR-free Library Prep Kit (NEB #E6177) were pooled at equimolar concentrations and sequenced on the Illumina NovaSeq 6000 instrument. The total number of reads from all libraries was summed, and the fraction of the total reads contributed by each library was determined (expected fraction per library = 0.26%). All 384 libraries clustered efficiently and were represented at approximately the expected frequency.
产品类别:
NEBNext® Multiplex Oligos (Adaptors & Primers) Products,
Next Generation Sequencing Library Preparation Products

  • 试剂盒组成

    本产品提供以下试剂或组分:

    NEB # 名称 组分货号 储存温度 数量 浓度
    • E7878S     -20    
        NEBNext® UMI DNA Adaptor Plate Set 4 E7879AVIAL -20 1 x 2.5 μl/well 20 µM
        NEBNext® Primer Mix E7397AVIAL -20 1 x 0.48 ml Not Applicable
        NEBNext® UMI Adaptor Dilution Buffer E7398AVIAL -20 2 x 2.5 ml Not Applicable
    • E7878L     -20    
        NEBNext® UMI DNA Adaptor Plate Set 4 E7879AVIAL -20 4 x 2.5 μl/well 20 µM
        NEBNext® Primer Mix E7397AAVIAL -20 2 x 0.96 ml Not Applicable
        NEBNext® UMI Adaptor Dilution Buffer E7398AAVIAL -20 1 x 20 ml Not Applicable

  • 相关产品

    相关产品

    • NEBNext® 多样本接头引物试剂盒 1(Unique 双端 Index 引物,UMI 接头,适用于 DNA)
    • NEBNext® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 2)
    • e7876nebnext-multiplex-oligos-for-illumina-unique-dual-index-umi-adaptors-dna-set-3

操作说明、说明书 & 用法

  • 操作说明

    1. Where can I find protocols for using NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4 (NEB #E7395, #E7874, #E7876, #E7878) with NEBNext Ultra II reagents?

  • 说明书

    产品说明书包含产品使用的详细信息、产品配方和质控分析。

    • manualE7395_E7874_E7876_E7878
    • manualE6177_E7805 w UMI Adaptors DNA
    • manualE7103_E7645 w UMI Adaptors DNA
    • manualE7595 w UMI Adaptors DNA

  • 使用指南

    • Forward Strand Workflow Sample Sheet for E7878 UMI: NovaSeq 6000 with v1.0 reagent kits, MiniSeq with Rapid reagent kits, MiSeq, HiSeq 2000/2500 (paired-end flow cell), HiSeq 3000/4000 (single-read flow cell)
    • Forward Strand Workflow Sample Sheet for E7878: NovaSeq 6000 with v1.0 reagent kits, MiniSeq with Rapid reagent kits, MiSeq, HiSeq 2000/2500 (paired-end flow cell), HiSeq 3000/4000 (single-read flow cell)
    • Reverse Complement Workflow Sample Sheet for E7878 UMI: iSeq 100, MiniSeq with Standard reagent kits, NextSeq Systems, NovaSeq 6000 with v1.5 reagent kits, HiSeq 2000/2500 (single-read flow cell), HiSeq 3000/4000 (paired-end flow cell)
    • Reverse Complement Workflow Sample Sheet for E7878: iSeq 100, MiniSeq with Standard reagent kits, NextSeq Systems, NovaSeq 6000 with v1.5 reagent kits, HiSeq 2000/2500 (single-read flow cell), HiSeq 3000/4000 (paired-end flow cell)

工具 & 资源

  • 选择指南

    • NEBNext® Multiplex Oligos Selection Chart

FAQs & 问题解决指南

  • FAQs

    1. What is the difference between NEBNext Unique Dual Index UMI Adaptors and NEBNext Adaptors for use with multiplex primers?
    2. What are the main applications for the NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4?
    3. How long are the UMIs and where are they on the adaptors?
    4. How are UMIs sequenced, and where can I find them?
    5. Can I skip UMI sequencing if I don’t need the UMIs for my applications?
    6. Are the NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4 compatible with NEBNext reagents for Illumina library preparation?
    7. Are the NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4 compatible with commercially available library prep reagents?
    8. How many reactions worth of the UMI adaptors are in each well?
    9. Are the adaptors methylated?
    10. What is the concentration of the adaptors and PCR primer mix in the NEBNext Multiplex Oligos (Unique Dual Index UMI Adaptors DNA Sets 1-4)?
    11. How many indices are available with NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Sets1-4)? 
    12. Are the NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4 validated in next generation sequencing workflows?
    13. Are the NEBNext UMI Adaptors compatible with single-end and paired-end sequencing?
    14. Do I need to spike in custom sequencing primers when sequencing libraries made with NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Sets 1-4) on the Illumina platforms? 
    15. Can I perform single read runs and still get both index sequences? Can I run both single read and paired-end recipes with dual-indexed libraries?
    16. Where can I find the sample sheets for the NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4?
    17. What sequences need to be trimmed for NEBNext libraries that are sequenced on an Illumina instrument?

Next® Multiplex Oligos for Illumina® (Methylated Adaptor, Index Primers Set 1) |NEB酶试剂 New England Biolabs

上海金畔生物科技有限公司代理New England Biolabs(NEB)酶试剂全线产品,欢迎访问官网了解更多产品信息和订购。

产品信息

Next® Multiplex Oligos for Illumina® (Methylated Adaptor, Index Primers Set 1) |

Incorporating a novel hairpin loop structure, the NEBNext adaptor ligates with increased efficiency to end-repaired, dA-tailed DNA. The loop contains a U, which is removed by treatment with USER® Enzyme (a mix of UDG and Endo VIII), to open up the loop and make it available as a substrate for PCR. During PCR, barcodes can be incorporated by use of the NEBNext index primers, thereby enabling multiplexing.

NEBNext oligos can be used with NEBNext products, and with other standard Illumina-compatible library preparation protocols.

产品类别:
Discontinued (<3 years)

  • 特性和用法

    需要但不提供的材料

    Compatible with the following library preparation kits:
    NEBNext Ultra™ II DNA Library Prep Kit for Illumina (#E7645),
    NEBNext Ultra™ DNA Library Prep Kit for Illumina (#E7370),
    NEBNext DNA Library Prep Master Mix Set for Illumina (#E6040), or
    NEBNext DNA Library Prep Reagent Set for Illumina (#E6000)

    NEB EpiMark® Bisulfite Conversion Kit (NEB # E3318S)
    NEB EpiMark Hot Start Taq DNA Polymerase (NEB # M0490S)

    10 mM dNTPs
    Freshly prepared 80% Ethanol
    Magnetic rack or plate (e.g., NEBNext® Magnetic Separation Rack (NEB #S1515S), Alpaqua ® 96S Super Magnet Plate (#A001322), or equivalent)
    DNA LoBind® Tubes (Eppendorf®)/PCR Plates
    Agencourt® AMPure® XP Beads (Beckman Coulter, Inc. #A63881)
    Bioanalyzer® (Agilent® Technologies, Inc.)
    Nuclease Free Water
    0.1X TE (or 10 mM Tris-HCl, pH 7.5-8.0)

操作说明、说明书 & 用法

  • 操作说明

    1. Please see manual (NEB #E7535) for protocols

  • 说明书

    产品说明书包含产品使用的详细信息、产品配方和质控分析。

    • manualE7535

  • 使用指南

    • E7535 NebNext Multiple Oligos for Illumina Sample Sheet

FAQs & 问题解决指南

  • FAQs

    1. What are the major applications of NEBNext Methylated Adaptor for Illumina?
    2. Is library prep workflow different when NEBNext Methylated Adaptor is used?
    3. How is NEBNext Methylated Adaptor (NEB #E7535) different from NEBNext adaptor for Illumina (NEB #E7335 & #E7350)?
    4. How do I know the concentration of my index primers? 
    5. What should I do if the sample sheet from the NEB.com website is not compatible with the software version I am using?

GM Maize Multiplex PCR Marker 转基因玉米多重PCR标记


GM Maize Multiplex PCR Marker

转基因玉米多重PCR标记

品牌:Nippon Gene
CAS No.:
储存条件:室温
纯度:
产品编号

(生产商编号)

等级 规格 运输包装 零售价(RMB) 库存情况 参考值

318-07251

50uL 咨询


* 干冰运输、大包装及大批量的产品需酌情添加运输费用


* 零售价、促销产品折扣、运输费用、库存情况、产品及包装规格可能因各种原因有所变动,恕不另行通知,确切详情请联系上海金畔生物科技有限公司。